mirror of
https://github.com/CCOSTAN/Home-AssistantConfig.git
synced 2025-02-15 14:16:08 +00:00
Going Old School Non Pythonic Brute Force.
This commit is contained in:
parent
0d7239079d
commit
368ee5a94a
19
README.md
19
README.md
@ -89,6 +89,9 @@ https://i.imgur.com/xy10yI1.png
|
||||
|
||||
resource for my RF switches. (MQTT) bit.ly/2gBiOqz
|
||||
|
||||
https://www.reddit.com/r/amazonecho/comments/5he8o7/diy_ir_blaster_10_instructions_inside/?st=IWIDBGRT&sh=dd117f28
|
||||
|
||||
|
||||
#Lab notes:
|
||||
|
||||
```yaml
|
||||
@ -126,22 +129,6 @@ Then simply use that in your light turn off automation:
|
||||
data:
|
||||
entity_id: light.hue_color_lamp_1
|
||||
|
||||
|
||||
- automation:
|
||||
alias: Random GLeft
|
||||
initial_state: False
|
||||
hide_entity: False
|
||||
trigger:
|
||||
platform: time
|
||||
seconds: '/5'
|
||||
action:
|
||||
service: homeassistant.turn_on
|
||||
entity_id:
|
||||
- light.gright
|
||||
data:
|
||||
effect: random
|
||||
transition: 1
|
||||
brightness: 255
|
||||
|
||||
|
||||
- platform: template
|
||||
|
69
script/Reliability.yaml
Executable file
69
script/Reliability.yaml
Executable file
@ -0,0 +1,69 @@
|
||||
######################################################################################################
|
||||
###Script to run every 30 minutes to check if 433 RF Switches are in the state they should be.
|
||||
### Sample Call
|
||||
# action:
|
||||
# - service: script.reliability
|
||||
######################################################################################################
|
||||
|
||||
# {% macro swTest(onoff) %} - service: switch.turn_{{ states(onoff) }}
|
||||
# entity_id: {{ onoff }}{% endmacro %}
|
||||
|
||||
# switch_check:
|
||||
# sequence:
|
||||
# {{ swTest("switch.foyer_outlet") }}
|
||||
# {{ swTest("switch.printer_outlet") }}
|
||||
# {{ swTest("switch.garage_outlet") }}
|
||||
# {{ swTest("switch.den_outlet") }}
|
||||
# {{ swTest("switch.living_room_outlet") }}
|
||||
# {{ swTest("switch.living_room_amp") }}
|
||||
|
||||
switch_check:
|
||||
sequence:
|
||||
- service_template: >
|
||||
{% if states.switch.foyer_outlet == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.foyer_outlet
|
||||
- delay: '00:00:30'
|
||||
- service_template: >
|
||||
{% if states.switch.printer_outlet == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.printer_outlet
|
||||
- delay: '00:00:30'
|
||||
- service_template: >
|
||||
{% if states.switch.garage_outlet == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.garage_outlet
|
||||
- delay: '00:00:30'
|
||||
- service_template: >
|
||||
{% if states.switch.den_outlet == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.den_outlet
|
||||
- delay: '00:00:30'
|
||||
- service_template: >
|
||||
{% if states.switch.kitchen_Accents == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.kitchen_Accents
|
||||
- delay: '00:00:30'
|
||||
- service_template: >
|
||||
{% if states.switch.living_room_amp == 'on' %}
|
||||
switch.turn_on
|
||||
{% else %}
|
||||
switch.turn_off
|
||||
{% endif %}
|
||||
entity_id: switch.living_room_amp
|
||||
|
@ -1,18 +0,0 @@
|
||||
######################################################################################################
|
||||
###Script to run every 30 minutes to check if 433 RF Switches are in the state they should be.
|
||||
### Sample Call
|
||||
# action:
|
||||
# - service: script.reliability
|
||||
######################################################################################################
|
||||
|
||||
{% macro swTest(onoff) %} - service: switch.turn_{{ states(onoff) }}
|
||||
entity_id: {{ onoff }}{% endmacro %}
|
||||
|
||||
switch_check:
|
||||
sequence:
|
||||
{{ swTest("switch.foyer_outlet") }}
|
||||
{{ swTest("switch.printer_outlet") }}
|
||||
{{ swTest("switch.garage_outlet") }}
|
||||
{{ swTest("switch.den_outlet") }}
|
||||
{{ swTest("switch.living_room_outlet") }}
|
||||
{{ swTest("switch.living_room_amp") }}
|
Loading…