added additional template samples.
This commit is contained in:
parent
bccfd3177b
commit
47beb50914
|
@ -518,6 +518,29 @@ ZWave Smart Switch - 5.93 minutes ago
|
|||
ZWave Stick - 8.82 minutes ago
|
||||
```
|
||||
|
||||
## 8a. Converting Seconds to Days, Hours, Minutes, and Seconds
|
||||
|
||||
To convert given seconds to Days, hours, minutes and seconds, use the script below:
|
||||
|
||||
```
|
||||
{% set seconds = 641200 %}
|
||||
{%- set map = {
|
||||
'Week': (seconds / 604800) % 604800,
|
||||
'Day': (seconds / 86400) % 7,
|
||||
'Hour': (seconds / 3600) % 24,
|
||||
'Minute': (seconds / 60) % 60,
|
||||
'Second': (seconds % 60)
|
||||
}
|
||||
-%}
|
||||
|
||||
{% for item in map if map[item] | int > 0 -%}
|
||||
{%- if loop.first %}{% elif loop.last %}, and {% else %}, {% endif -%}
|
||||
{{ map[item]|int|round(0) }} {{ item }} {{- 's' if map[item]|int|round(0) > 1 }}
|
||||
{%- endfor -%}
|
||||
```
|
||||
|
||||
This returns `1 Week, 10 Hours, 6 Minutes, and 40 Seconds`.
|
||||
|
||||
## 9. Word Wrapping long text into multiple lines:
|
||||
|
||||
To wrap text to a certain number of characters, use the following script:
|
||||
|
|
|
@ -197,7 +197,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="3" name="Upstairs Multi Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3079" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Associations">
|
||||
<Node id="3" name="Upstairs Multi Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3079" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Manufacturer id="86" name="Aeotec">
|
||||
<Product type="102" id="4a" name="ZW074 MultiSensor Gen5" />
|
||||
</Manufacturer>
|
||||
|
@ -208,7 +208,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
|
||||
<SensorMap index="0" type="46" />
|
||||
<SensorMap index="0" type="62" />
|
||||
<SensorMap index="0" type="193" />
|
||||
|
@ -217,7 +217,7 @@
|
|||
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="64.0" />
|
||||
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="27" />
|
||||
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="27" />
|
||||
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
</CommandClass>
|
||||
|
@ -350,7 +350,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="82" />
|
||||
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="80" />
|
||||
</CommandClass>
|
||||
<CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true">
|
||||
<Instance index="1" />
|
||||
|
@ -379,7 +379,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="4" name="Two Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="4" name="Two Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="4" id="3" name="Garage Door Tilt Sensor" />
|
||||
</Manufacturer>
|
||||
|
@ -490,7 +490,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="5" name="Single Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="5" name="Single Car Garage Door Tilt Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="4" id="3" name="Garage Door Tilt Sensor" />
|
||||
</Manufacturer>
|
||||
|
@ -710,7 +710,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="11" name="Front Room Multi Sensor" location="" basic="4" generic="33" specific="1" roletype="6" devicetype="3079" nodetype="0" type="Routing Multilevel Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="11" name="Front Room Multi Sensor" location="" basic="4" generic="33" specific="1" roletype="6" devicetype="3079" nodetype="0" type="Routing Multilevel Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="86" name="Aeotec">
|
||||
<Product type="102" id="64" name="ZW100 MultiSensor 6" />
|
||||
</Manufacturer>
|
||||
|
@ -728,9 +728,9 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="60.2" />
|
||||
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="3" />
|
||||
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="43" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="66.4" />
|
||||
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="35" />
|
||||
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
</CommandClass>
|
||||
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
|
||||
|
@ -974,7 +974,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="15" name="ZWave Smart Switch" location="" basic="4" generic="16" specific="1" roletype="5" devicetype="1792" nodetype="0" type="Binary Power Switch" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" refreshonnodeinfoframe="false" query_stage="Neighbors">
|
||||
<Node id="15" name="ZWave Smart Switch" location="" basic="4" generic="16" specific="1" roletype="5" devicetype="1792" nodetype="0" type="Binary Power Switch" listening="true" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" refreshonnodeinfoframe="false" query_stage="Complete">
|
||||
<Manufacturer id="86" name="Aeotec">
|
||||
<Product type="103" id="60" name="ZW096 Smart Switch 6" />
|
||||
</Manufacturer>
|
||||
|
@ -1007,10 +1007,10 @@
|
|||
<CommandClass id="50" name="COMMAND_CLASS_METER" version="3" request_flags="2" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="decimal" genre="user" instance="1" index="0" label="Energy" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="59.927" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="59.867" />
|
||||
<Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="65535" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Previous Reading" units="kWh" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="59.927" />
|
||||
<Value type="int" genre="user" instance="1" index="2" label="Interval" units="seconds" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="-2147483648" max="2147483647" value="9506" />
|
||||
<Value type="decimal" genre="user" instance="1" index="8" label="Power" units="W" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
|
||||
<Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="123.596" />
|
||||
<Value type="decimal" genre="user" instance="1" index="16" label="Voltage" units="V" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="122.257" />
|
||||
<Value type="decimal" genre="user" instance="1" index="20" label="Current" units="A" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0.000" />
|
||||
<Value type="bool" genre="user" instance="1" index="32" label="Exporting" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
|
||||
<Value type="button" genre="system" instance="1" index="33" label="Reset" units="" read_only="false" write_only="true" verify_changes="false" poll_intensity="0" min="0" max="0" />
|
||||
|
@ -1190,8 +1190,8 @@
|
|||
<Item label="Saturday" value="6" />
|
||||
<Item label="Sunday" value="7" />
|
||||
</Value>
|
||||
<Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="3" />
|
||||
<Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="24" />
|
||||
<Value type="byte" genre="user" instance="1" index="1" label="Hour" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="6" />
|
||||
<Value type="byte" genre="user" instance="1" index="2" label="Minute" units="" read_only="false" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="2" />
|
||||
</CommandClass>
|
||||
<CommandClass id="130" name="COMMAND_CLASS_HAIL" version="1" request_flags="4" after_mark="true" innif="true">
|
||||
<Instance index="1" />
|
||||
|
@ -1328,7 +1328,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="17" name="Stairs Motion Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="17" name="Stairs Motion Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="4" id="1" name="Motion Detector" />
|
||||
</Manufacturer>
|
||||
|
@ -1339,7 +1339,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
|
||||
<SensorMap index="0" type="255" />
|
||||
</CommandClass>
|
||||
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1">
|
||||
|
@ -1369,7 +1369,7 @@
|
|||
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="8" />
|
||||
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="11" label="Power Management" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
</CommandClass>
|
||||
<CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true">
|
||||
|
@ -1416,7 +1416,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="128" name="COMMAND_CLASS_BATTERY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="100" />
|
||||
<Value type="byte" genre="user" instance="1" index="0" label="Battery Level" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="99" />
|
||||
</CommandClass>
|
||||
<CommandClass id="132" name="COMMAND_CLASS_WAKE_UP" version="2" request_flags="2" innif="true">
|
||||
<Instance index="1" />
|
||||
|
@ -1703,7 +1703,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="25" name="Basement Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="4" id="2" name="Unknown: type=0004, id=0002" />
|
||||
</Manufacturer>
|
||||
|
@ -1809,7 +1809,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Session">
|
||||
<Node id="27" name="Wallmote" location="" basic="4" generic="24" specific="1" roletype="4" devicetype="7172" nodetype="0" type="Basic Wall Controller" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Manufacturer id="86" name="Aeotec">
|
||||
<Product type="102" id="82" name="ZW130 WallMote Quad" />
|
||||
</Manufacturer>
|
||||
|
@ -2023,7 +2023,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="28" name="Audio Detector" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3073" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="28" name="Audio Detector" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3073" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="5" id="f" name="FireFighter" />
|
||||
</Manufacturer>
|
||||
|
@ -2038,7 +2038,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="7" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="66.74" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="67.46" />
|
||||
</CommandClass>
|
||||
<CommandClass id="90" name="COMMAND_CLASS_DEVICE_RESET_LOCALLY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
|
@ -2132,7 +2132,7 @@
|
|||
</CommandClass>
|
||||
</CommandClasses>
|
||||
</Node>
|
||||
<Node id="29" name="Garage Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="CacheLoad">
|
||||
<Node id="29" name="Garage Door Sensor" location="" basic="4" generic="7" specific="1" roletype="6" devicetype="3072" nodetype="0" type="Notification Sensor" listening="false" frequentListening="false" beaming="true" routing="true" max_baud_rate="40000" version="4" query_stage="Complete">
|
||||
<Manufacturer id="14a" name="Ecolink">
|
||||
<Product type="4" id="2" name="Unknown: type=0004, id=0002" />
|
||||
</Manufacturer>
|
||||
|
@ -2391,7 +2391,7 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="48" name="COMMAND_CLASS_SENSOR_BINARY" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="True" />
|
||||
<Value type="bool" genre="user" instance="1" index="0" label="Sensor" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="False" />
|
||||
<SensorMap index="0" type="15" />
|
||||
<SensorMap index="0" type="27" />
|
||||
<SensorMap index="0" type="31" />
|
||||
|
@ -2405,9 +2405,9 @@
|
|||
</CommandClass>
|
||||
<CommandClass id="49" name="COMMAND_CLASS_SENSOR_MULTILEVEL" version="5" innif="true">
|
||||
<Instance index="1" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="69.8" />
|
||||
<Value type="decimal" genre="user" instance="1" index="1" label="Temperature" units="F" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="70.5" />
|
||||
<Value type="decimal" genre="user" instance="1" index="3" label="Luminance" units="lux" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="29" />
|
||||
<Value type="decimal" genre="user" instance="1" index="5" label="Relative Humidity" units="%" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="27" />
|
||||
<Value type="decimal" genre="user" instance="1" index="27" label="Ultraviolet" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="0" />
|
||||
<Value type="decimal" genre="user" instance="1" index="37" label="Radon Concentration" units="bq/m3" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="0" value="60" />
|
||||
</CommandClass>
|
||||
|
@ -2580,7 +2580,7 @@
|
|||
<Value type="byte" genre="user" instance="1" index="0" label="Alarm Type" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="1" label="Alarm Level" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="2" label="SourceNodeId" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="254" />
|
||||
<Value type="byte" genre="user" instance="1" index="10" label="Burglar" units="" read_only="true" write_only="false" verify_changes="false" poll_intensity="0" min="0" max="255" value="0" />
|
||||
</CommandClass>
|
||||
<CommandClass id="114" name="COMMAND_CLASS_MANUFACTURER_SPECIFIC" version="1" request_flags="4" innif="true">
|
||||
<Instance index="1" />
|
||||
|
|
Loading…
Reference in New Issue