layout: page
|
|
title: Setup UPS Battery on Ubuntu
|
|
description: Got a battery backup? Here is how you can set it up...
|
|
---
|
|
|
|
<h1>Introduction</h1>
|
|
|
|
<p>The package apcupsd provides a daemon which will monitor your APC UPS, and shutdown the system when power is no longer being supplied to the UPS.</p>
|
|
|
|
<h2>Prerequisites</h2>
|
|
|
|
<p>An APC UPS. The apcupsd daemon works with most APC Smart-UPS models, as well as most simple signaling models, such as Back-UPS, and BackUPS-Office.</p>
|
|
|
|
<h2>Installation</h2>
|
|
|
|
<h3>When using systemd</h3>
|
|
|
|
<p>This example assumes you are using a APC Smart-UPS 750 via USB.</p>
|
|
|
|
<p>First, install the apcupsd package via a terminal: </p>
|
|
|
|
```
|
|
sudo apt-get -y install apcupsd
|
|
```
|
|
|
|
Next, backup the original configuration files:
|
|
```
|
|
sudo cp /etc/apcupsd/apcupsd.conf /etc/apcupsd/apcupsd.conf.bak
|
|
```
|
|
|
|
Next, edit the configuration files:
|
|
```
|
|
sudo nano /etc/apcupsd/apcupsd.conf
|
|
```
|
|
|
|
```
|
|
UPSNAME smartups750
|
|
UPSCABLE usb
|
|
UPSTYPE usb
|
|
DEVICE
|
|
POLLTIME 60
|
|
```
|
|
|
|
```
|
|
sudo cp /etc/default/apcupsd /etc/default/apcupsd.bak
|
|
```
|
|
|
|
```
|
|
sudo nano /etc/default/apcupsd
|
|
```
|
|
|
|
```
|
|
ISCONFIGURED=yes
|
|
```
|
|
|
|
<p>Now one may check the status of the UPS via a terminal: </p>
|
|
```
|
|
apcaccess status
|
|
```
|
|
|
|
When you run the command, you will see something like this...
|
|
|
|
```
|
|
APC : 001,027,0660
|
|
DATE : 2015-09-26 18:39:09 -0500
|
|
HOSTNAME : pc
|
|
VERSION : 3.14.12 (29 March 2014) debian
|
|
UPSNAME : smartups750
|
|
CABLE : USB Cable
|
|
DRIVER : USB UPS Driver
|
|
UPSMODE : Stand Alone
|
|
STARTTIME: 2015-09-26 18:39:08 -0500
|
|
MODEL : Smart-UPS 750
|
|
STATUS : ONLINE
|
|
BCHARGE : 100.0 Percent
|
|
TIMELEFT : 51.0 Minutes
|
|
MBATTCHG : 5 Percent
|
|
MINTIMEL : 3 Minutes
|
|
MAXTIME : 0 Seconds
|
|
ALARMDEL : 30 Seconds
|
|
BATTV : 27.1 Volts
|
|
NUMXFERS : 0
|
|
TONBATT : 0 Seconds
|
|
CUMONBATT: 0 Seconds
|
|
XOFFBATT : N/A
|
|
STATFLAG : 0x05000008
|
|
MANDATE : 2010-07-08
|
|
SERIALNO : XXXXXXXXXXXX
|
|
NOMBATTV : 24.0 Volts
|
|
FIRMWARE : COM 02.1 / UPS.05.D
|
|
END APC : 2015-09-26 18:39:19 -0500
|
|
```
|
|
|
|
In order to run `apctest`, one must first stop apcupsd via a terminal:
|
|
|
|
```
|
|
sudo systemctl stop apcupsd
|
|
```
|
|
|
|
Otherwise, one may see the following error:
|
|
```
|
|
sudo apctest
|
|
2015-09-26 18:57:38 apctest 3.14.12 (29 March 2014) debian
|
|
Checking configuration ...
|
|
sharenet.type = Network & ShareUPS Disabled
|
|
cable.type = USB Cable
|
|
mode.type = USB UPS Driver
|
|
apctest FATAL ERROR in apctest.c at line 335
|
|
Unable to create UPS lock file.
|
|
If apcupsd or apctest is already running,
|
|
please stop it and run this program again.
|
|
apctest error termination completed
|
|
```
|
|
|
|
Then execute the collowing command:
|
|
```
|
|
sudo apctest
|
|
```
|
|
|
|
That will show the following output:
|
|
```
|
|
2015-09-26 18:59:38 apctest 3.14.12 (29 March 2014) debian
|
|
Checking configuration ...
|
|
sharenet.type = Network & ShareUPS Disabled
|
|
cable.type = USB Cable
|
|
mode.type = USB UPS Driver
|
|
Setting up the port ...
|
|
Doing prep_device() ...
|
|
|
|
You are using a USB cable type, so I'm entering USB test mode
|
|
Hello, this is the apcupsd Cable Test program.
|
|
This part of apctest is for testing USB UPSes.
|
|
|
|
Getting UPS capabilities...SUCCESS
|
|
|
|
Please select the function you want to perform.
|
|
|
|
1) Test kill UPS power
|
|
2) Perform self-test
|
|
3) Read last self-test result
|
|
4) View/Change battery date
|
|
5) View manufacturing date
|
|
6) View/Change alarm behavior
|
|
7) View/Change sensitivity
|
|
8) View/Change low transfer voltage
|
|
9) View/Change high transfer voltage
|
|
10) Perform battery calibration
|
|
11) Test alarm
|
|
12) View/Change self-test interval
|
|
Q) Quit
|
|
|
|
Select function number:
|
|
```
|
|
|
|
Once done, start apcupsd:
|
|
|
|
```
|
|
sudo systemctl start apcupsd
|
|
```
|
|
|
|
You can also check the status by running:
|
|
|
|
```
|
|
sudo systemctl status apcupsd
|
|
```
|
|
|
|
|